Rack Servers
Rack Servers get their name from the type of cabinet, used to store them, called a rack. The rack contains bays used to house the servers. One or more rack servers can be placed vertically within the frame and even secured with screws when necessary. The bays also have room for other equipment required to run the servers. The racks used must adhere to IEEE standards.
Dell PowerEdge R740 Servers
Maximize your application performance with the Dell PowerEdge R740 Server which brings you the perfect balance of accelerator cards, storage and compute resources in a 2U, 2-socket platform. Invest in a Dell R740 Rack Servers to transform your data center for VDI, artificial intelligence and software-defined storage (SDS).
HPE ProLiant DL380 Gen10 Servers
The HPE ProLiant DL380 Gen10 Server adaptable for diverse workloads and environments, the secure 2P 2U HPE ProLiant DL380 Gen10 Rack Servers delivers world-class performance with the right balance of expandability and scalability. Designed for supreme versatility and resiliency while being backed by a comprehensive warranty make it ideal for multiple environments from Containers to Cloud to Big Data.
Table 1. Dell R740 vs. HPE DL380 G10.
SERVER MODEL | Dell PowerEdge R740 Server | HPE ProLiant DL380 Gen10 Servers |
CPU | (2) Intel® Xeon® Scalable processors (1st and 2nd Generation) Bronze, Silver, Gold,Platinum Platinum 8180M (205W) | 1 -2 Intel® Xeon® processors 8100/6100/5100/4100/3100 8080/8010M |
Chipset | Intel C621 | Intel C621 |
RAM | 24 128GB/2667MHz/LRDIMM Support for 2933MHz RDIMM since April 2019 | 24 128GB/2667MHz/LRDIMM 32GB/2667MHZ/RDIMM |
RAM Total Capacity | 3TB | 3.0TB |
Permanent memory | 12 NVDIMM,up to 192GB | 1216GB NVDIMM,up to 192GB |
Storage controller Model | 6Gbps SATA Controller: onbord SW RAID S140 12Gbps RAID Controller: RAID Controller H730P, 12Gb/s SAS, 6Gb/s SATA , 2GB DDR3 NV SDRAM, PCIe, support SAS/SATA/SSD; RAID Controller H740P, 12Gb/s SAS, 6Gb/s SATA , 8GB DDR4-2133 NV DRAM, PCIe, support SAS/SATA/SSD; RAID Controller H330, 12Gb/s SAS, 6Gb/s SATA, support SAS/SATA/SSD, no cache, PCIe Internal controller:HBA330 12Gb/s SAS, 6Gb/s SATA, No Cache, No RAID, Pass through only External PERC(RAID):RAID Controller H840 RAID Controller H840, 2Gb/s SAS, 6Gb/s SATA, 8GB NV, PCIe, support SAS/SATA/SSD, 0/1/5/6/10/50/60 External HBA(No RAID):12 Gbps SAS HBA No Cache, No RAID, Pass through only | 1 S100i 1 E208i-a/E208e-p 1 P408i-a/P408e-p 1 P816i-a |
Cache Size/Maximum | 8GB | 4GB |
Cache Protection Type | / | / |
Battery or Capacitance | BATTERY | BATTERY |
Main technical characteristics | Controller Chip:H730P(LSISAS 3108),H740P(LSISAS 3508), H330(LSI SAS3008) RAID Support:H730P (0/1/5/6/10/50/60), H740P(0/1/5/6/10/50/60), H330 (0/1/5/10/50), S140 (0/1/5/10) | 12Gb SAS, up to 240 pieces |
Number of SD cards | 2 | 1 (optional 2) |
SD card capacity | 64GB | 8GB dual MicroSD card pack or 32GB single MicroSD card pack |
SD cards can form RAID levels | 1 | N/A |
M.2 quantity | 2 | 2 |
M. 2 single chip capacity | 240GB | 1.92TB |
M.2 RAID levels | 1 | RAID 1 |
Network card Sub-Card (NDC Card Type) | 4 1GE interfaces,or 2 10GE plus 2 1GE interfaces,or 4 10GE interfaces,or 2 25GE interfaces | Default 4x1Gb(FlexibleLOM) Optional 2x10Gb/4x10Gb/2x25Gb |
PCIe (occupies a standard slot) | YES | No (embedded, no slot occupied) |
GPU Max Supported Blocks | 3 full-width 300W or 6 single-width 150W | 3 full widths or 5 single widths |
GPU model | Nvidia Tesla V100/P100, K80, K40, Grid M60, M10, P4, Quadro P4000 | Nvidia Tesla P4/P40/P100/V100/M60 Quadro P2000/P4000/P6000 AMD Radeon Instinct MI25 |
FPGA | ||
FPGA Maximum Supported Blocks | Unknown | / |
FPGA model | POST RTS | / |
Hard drive backplane | ||
Type (including the maximum number of supported hard disks) | Supports up to 16 x 2.5″ hard drives a. 16 x 2.5″ SAS/SATA b. 8 x 2.5″ SAS/SATA Supports up to 8 x 3.5 “hard drives a. 8 x 2.5” SAS/SATA No support for rear or internal hard drives | Max 24+6×2.5″,Max 12+4+3×3.5″ and 2×2.5″; Max 20 front NVMe |
Whether to support hard disk hot swap | YES | YES |
Hard disk configuration | ||
Model and quantity | SAS/SATA/SSD; 16*2.5”/8*3.5” | SATA/SAS HDD/SSD |
Chassis | ||
Dimensions (cm) | 86.5mm (height) * 482mm (width) * 751.34mm (depth) (including safety panel) 28.6kg | x2.5″:8.73 x 44.55 x 67.94 cm x3.5″:8.73 x 44.55 x 73.02 cm |
Ventilation method | Air-cooled | Forward wind |
Temperature | ||
Equipment operating temperature range (°C) | 10°C to 35°C | ASHARE A4 5-45℃ |
Equipment working humidity range | 10% to 80% | 8% – 90% |
Hot-swappable power supplies | ||
Nominal power of single power supply (W) | Titanium gold 750W, Platinum class 495W, 750W, 1100W, 1600W和2000W240V HVDC 750W 336V HVDC 1100W -48V DC 1100W | HPE universal slot redundant power module 550 w /800 w /1600 w, up to 96% efficiency conversion |
Quantity | 2 | 2020\1\2 |
Dual power mode | Redundancy | Redundancy |
Input method | 220VAC/48VDC/380HVDC/240HVDC | 240VAC/48VDC/380VDC |
PCI-E (I/O) | ||
Quantity | Up to 8 Gen3 slot (4 x16) | Up to 8 standard PCI-E 3.0 slots, 1 array card proprietary slot, and 1 FlexLOM network card slot |
USB port | ||
Quantity | 5 | 5 standard USB 3.0 (front 1, rear 1, internal 2), 2 additional USB ports can be added through Universal Media Bay (8×3.5″ chassis standard) |
Out-of-band management | ||
Yes or No | YES | YES |
The main function | IPMI 2.0 compliant IDRAC9 with life cycle controller (Express edition, Enterprise edition) Optional Quick Sync 2 wireless module | HPE iLO Standard with smart configuration (embedded), HPE OneView Standard (download required) (Standard), HPE iLO Advanced, HPE iLO Advanced Premium Security Edition and HPE OneView Advanced (optional) |
Energy management | YES | YES |
System cooling fan | Wind deflector plate, vector heat dissipation | 6 |
LCD display | Optional | Systems Insight Display |
Host front panel with keyhole and key | YES | YES |
Table 2. Dell R740 vs. Lenovo SR650.
Server Model | Dell PowerEdge R740 Server | Lenovo ThinkSystem SR650 Rack Servers |
CPU | (2) Intel® Xeon® Scalable processors (1st and 2nd Generation) Bronze, Silver, Gold,Platinum Platinum 8180M (205W) | Intel Xeon Bronze, Silver, Gold, or Platinum processors Intel Xeon Platinum 8180 28C |
Chipset | Intel C621 | Intel C624 |
RAM | 24 128GB/2667MHz/LRDIMM Support for 2933MHz RDIMM since April 2019 | 24 DDR4 DIMM slots,up to 2666MT/s |
RAM Total Capacity | 3TB | 3TB |
Permanent memory | 12 NVDIMM,up to 192GB | No |
Storage controller | ||
Storage controller Model | 6Gbps SATA Controller: onbord SW RAID S140 12Gbps RAID Controller: RAID Controller H730P, 12Gb/s SAS, 6Gb/s SATA , 2GB DDR3 NV SDRAM, PCIe, support SAS/SATA/SSD; RAID Controller H740P, 12Gb/s SAS, 6Gb/s SATA , 8GB DDR4-2133 NV DRAM, PCIe, support SAS/SATA/SSD; RAID Controller H330, 12Gb/s SAS, 6Gb/s SATA, support SAS/SATA/SSD, no cache, PCIe Internal controller:HBA330 12Gb/s SAS, 6Gb/s SATA, No Cache, No RAID, Pass through only External PERC(RAID):RAID Controller H840 RAID Controller H840, 2Gb/s SAS, 6Gb/s SATA, 8GB NV, PCIe, support SAS/SATA/SSD, 0/1/5/6/10/50/60 External HBA(No RAID):12 Gbps SAS HBA No Cache, No RAID, Pass through only | 8/16/24 port 12Gbps array card option: 12Gbps RAID controller: ThinkSystem RAID 530-8i PCIe 12Gb Adapter ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter12Gbps non-RAID HBA card: ThinkSystem 430-8i SAS/SATA 12Gb HBA ThinkSystem 430-16i SAS/SATA 12Gb HBA NVMe PCIe interfaces (non-RAID) Onboard NVMe interface (4-port) ThinkSystem 1610-4P NVMe Switch Adapter |
Cache Size/Maximum | 8GB | None, 1GB, 2GB, 4GB |
Cache Protection Type | / | None(530-8i, 730-8i), Flash backup(930-8i, 930-16i, 930-24i) |
Battery or Capacitance | Battery | Capacitance |
Main technical characteristics | Controller Chip:H730P(LSISAS 3108),H740P(LSISAS 3508), H330(LSI SAS3008) RAID Support:H730P (0/1/5/6/10/50/60), H740P(0/1/5/6/10/50/60), H330 (0/1/5/10/50), S140 (0/1/5/10) | Controller Chip:SAS3408(530-8i), SAS3108(730-8i), SAS3508(930-8i, 930-24i), SAS3516(930-16i), SAS3408(430-8i), SAS3416(430-16i) RAID Support:530-8i(0\1\10\5\50), 730-8i(0\1\10\5\50), 930-8i(0\1\10\5\50\6\60), 930-16i(0\1\10\5\50\6\60), 930-24i(0\1\10\5\50\6\60) |
SD Card | ||
Number of SD cards | 2 | Does not support SD |
SD card capacity | 64GB | N/A |
SD cards can form RAID levels | 1 | N/A |
M.2 | ||
M.2 quantity | 2 | 1 or 2 |
M. 2 single chip capacity | 240GB | ThinkSystem M.2 CV1 32GB ThinkSystem M.2 CV3 128GB |
M.2 RAID levels | 1 | RAID0, RAID1 |
Network card | ||
Sub-Card (NDC Card Type) | 4 1GE interfaces,or 2 10GE plus 2 1GE interfaces,or 4 10GE interfaces,or 2 25GE interfaces | No onboard, 1 LOM slot, LOM CARDS (Intel X722, incompatible 10/100mb rate) ThinkSystem 1Gb 2-port RJ45 LOM ThinkSystem 1Gb 4-port RJ45 LOM ThinkSystem 10Gb 2-port Base-T LOM ThinkSystem 10Gb 2-port SFP+ LOM ThinkSystem 10Gb 4-port Base-T LOM ThinkSystem 10Gb 4-port SFP+ LOM |
PCIe (occupies a standard slot) | YES | YES |
GPU | ||
GPU Max Supported Blocks | 3 full-width 300W or 6 single-width 150W | Up to 2 double widths |
GPU model | Nvidia Tesla V100/P100, K80, K40, Grid M60, M10, P4, Quadro P4000. | NVIDIA Tesla M60 GPU, PCIe (Passive) NVIDIA Tesla P100 16GB PCIe Passive GPU |
FPGA | ||
FPGA Maximum Supported Blocks | Unknown | N/A |
FPGA model | POST RTS | N/A |
Hard drive backplane | ||
Type (including the maximum number of supported hard disks) | Supports up to 16 x 2.5″ hard drives a. 16 x 2.5″ SAS/SATA b. 8 x 2.5″ SAS/SATA Supports up to 8 x 3.5 “hard drives a. 8 x 2.5” SAS/SATA No support for rear or internal hard drives | 16 2.5-inch SAS/SATA hot plug hard drives a. 8 2.5″ SAS/SATA + 8 2.5″ SAS/SATA b. 4 2.5″ SAS/SATA & 4 2.5″ AnyBay + 8 2.5″ SAS/SATA c. 4 2.5″ SAS/SATA & 4 2.5″ AnyBay + 4 2.5″ SAS/SATA & 4 2.5″ AnyBay 24 2.5-inch SAS/SATA hot plug hard drives a. 8 2.5″ SAS/SATA + 8 2.5″ SAS/SATA + 8 2.5″ SAS/SATA b. 4 2.5″ SAS/SATA & 4 2.5″ AnyBay + 8 2.5″ SAS/SATA + 8个 2.5″ SAS/SATA 8 3.5-inch SAS/SATA hot plug hard drives 14 3.5-inch SAS/SATA hot plug hard drives a. 12 3.5″ SAS/SATA (front) + 2 × 3.5″ SAS/SATA (rear) b. 8 3.5″ SAS/SATA & 4x 3.5″ AnyBay (front) + 2 × 3.5″ SAS/SATA (rear) |
Whether to support hard disk hot swap | YES | YES |
Hard disk configuration | ||
Model and quantity | SAS/SATA/SSD; 16*2.5”/8*3.5” | 2.5-inch 12Gbps SAS hard drive: 3.5-inch 12Gbps SAS hard drive: 2.5-inch 12Gbps NL-SAS hard drive: 3.5-inch 12Gbps NL-SAS hard drive: 3.5-inch 6Gbps SATA hard drive: 2.5-inch 6Gbps SATA hard drive: 2.5-inch SSD hard drive: NVMe PCIe interface:U.2 PX04PMB 800GB, U.2 PX04PMB 1.6TB, U.2 PX04PMB 960GB, U.2 PX04PMB 1.92TB, U.2 PM963 1.92TB, U.2 PM963 3.84TB |
Chassis | ||
Dimensions (cm) | 86.5mm (height) * 482mm (width) * 751.34mm (depth) (including safety panel) 28.6kg | 2U height Height: 87 mm (3.4 in) Width: 445 mm (17.5 in) Depth: 720 mm (28.3 in) |
Ventilation method | Air-cooled | Wind after wind |
Temperature | ||
Equipment operating temperature range (°C) | 10°C to 35°C | ASHRAE Class A4: 5 °C – 45 °C (41 °F – 113 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 125-m (410-ft) increase in altitude ASHRAE Class A3: 5 °C – 40 °C (41 °F – 104 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 175-m (574-ft) increase in altitude ASHRAE Class A2: 10 °C – 35 °C (50 °F – 95 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude |
Equipment working humidity range | 10% to 80% | ASHRAE Class A4: 8% – 90% (non-condensing); maximum dew point: 24 °C (75 °F) ASHRAE Class A3: 8% – 85% (non-condensing); maximum dew point: 24 °C (75 °F) ASHRAE Class A2: 8% – 80% (non-condensing); maximum dew point: 21 °C (70 °F) |
Hot-swappable power supplies | ||
Nominal power of single power supply (W) | Titanium gold 750W, Platinum class 495W, 750W, 1100W, 1600W和2000W240V HVDC 750W 336V HVDC 1100W -48V DC 1100W | 550W/750W/1100W/1600W,optional platinum, titanium power supply ThinkSystem 550W (230V/115V) Platinum Hot-Swap Power Supply ThinkSystem 750W (230/115V) Platinum Hot-Swap Power Supply ThinkSystem 750W (230V) Titanium Hot-Swap Power Supply ThinkSystem 1100W (230V/115V) Platinum Hot-Swap Power Supply ThinkSystem 1600W (230V) Platinum Hot-Swap Power Supply |
Quantity | 2 | 2 |
Dual power mode | Redundancy | N+N |
Input method | 220VAC/48VDC/380HVDC/240HVDC | Up to two redundant hot-swap 550 W, 750 W, or 1100 W (100 – 240 V), or 1600 W (200 – 240 V) High Efficiency Platinum AC power supplies, or 750 W (200 – 240 V) High Efficiency Titanium AC power supplies. |
PCI-E (I/O) | ||
Quantity | Up to 8 Gen3 slot (4 x16) | Up to 7 PCIE 3.0 slots (including 1 dedicated RAID adapter PCIE) LOM card slot Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, half-length (PCIe x16 slot is double-wide) Slot 2: PCIe 3.0 x8; full-height, half-length (not present if the slot 1 is PCIe x16 or slot 3 is ML2 x16) Slot 3: PCIe 3.0 x8, or ML2 x8, or ML2 x16; full-height, half-length Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar) Slot 5: PCIe 3.0 x16; full-height, half-length Slot 6: PCIe 3.0 x16; full-height, half-length Slot 7: PCIe 3.0 x8 (dedicated to an internal storage controller) |
USB port | ||
Quantity | 5 | Total 4 USB ports Front panel :1x USB 2.0 port with XClarity Controller access, 1x USB 3.0 port Rear panel :2x USB 3.0 ports |
Out-of-band management Yes or No | YES | YES |
The main function | IPMI 2.0 compliant IDRAC9 with life cycle controller (Express edition, Enterprise edition) Optional Quick Sync 2 wireless module | XClarity Controller (XCC) Standard, Advanced, Enterprise The features of the Standard version are included by default, and you can choose to upgrade to Advanced or Enterprise through Features on Demand (FoD) Support mobile management function (Xclarity Mobile App + front USB interface connection), Mobile App supports Android or iOS. |
Energy management | YES | Yes,Lenovo XClarity Energy Manager |
System cooling fan | Wind deflector plate, vector heat dissipation | 6 hot plug fans, support N+1 redundancy, 5 for 1 CPU, 6 for 2 CPU |
LCD display | OPTIONAL | N/A is diagnosed by Light path diagnostics |
Host front panel with keyhole and key | YES | Support, optional lock panel (ThinkSystem 1U Security Bezel) |
Interested in purchasing Rack Servers for your organization or reselling? Click here Promise Compute Technology